Anonymous | Login | 2024-12-02 17:55 EST |
Main | My View | View Issues | Change Log | Roadmap |
View Issue Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||||
ID | Project | Category | View Status | Date Submitted | Last Update | ||||||
0001814 | PacketFence | web admin | public | 2014-07-14 19:36 | 2014-07-15 12:58 | ||||||
Reporter | hagenbucher | ||||||||||
Assigned To | |||||||||||
Priority | normal | Severity | minor | Reproducibility | always | ||||||
Status | new | Resolution | open | ||||||||
Platform | i686 | OS | Ubuntu Server | OS Version | 12.04.4 LTS | ||||||
Product Version | devel | ||||||||||
Target Version | Fixed in Version | ||||||||||
Summary | 0001814: Uplinks only allowed to be numeric | ||||||||||
Description | You untick the usage of dynamic uplinks (how does it work?) The field "Uplink" is editable now but does not allow ports like: A1, A2, A3 or Trk1, Trk2 issue 1 a) Trk1, Trk2 ... are trunks (static) or link aggretaions (lacp) created manually on the switch CLI (do not confuse cisco usage of the word trunk) for 5400zl and 2910al series. issue 1 b) A1 is the first port on modul A on HP ProCurve 5400zl series. issue 2) If there is only one uplink port - which is perfectly fine with an lacp created link connected to a distributed trunk/multi chassis lag or if you don't care about redundancy - there should be the possibility of configuring one port only as uplink. | ||||||||||
Steps To Reproduce | Menu Configuration - Switches: - Click 'Add Switch' - Fill any non-numerical value to the file "Uplink" - The field and caption gets framed/written in red and you cannot save your edit. | ||||||||||
Additional Information | Tested with 4.3.0-201407140016 and 4.3.0 You can workaround issue number two by filling in "1, 1" if your only uplink port is port number 1. | ||||||||||
Tags | No tags attached. | ||||||||||
fixed in git revision | |||||||||||
fixed in mtn revision | |||||||||||
Attached Files | |||||||||||
Notes | |
(0003564) fdurand (administrator) 2014-07-15 07:18 |
Hello, when you define an uplink port it mean that it´s the ifIndex which is an integer. Regards Fabrice |
(0003565) hagenbucher (reporter) 2014-07-15 12:58 |
Hello Fabrice, thank you very much for clarifying this issue. It did help me a lot. for future reference: ifIndices for HP5400zl (max. of 288 ports as 5412zl) Trk1 is ifIndex 290 Trk2 is ifIndex 291 Trk3 is IfIndex 292 ifIndices for HP2910al (fixed port switch with 44 1000baseTX and 4 fiber ports) Trk1 is ifIndex 54 Trk2 is ifIndex 55 Kind regards, David |
Issue History | |||
Date Modified | Username | Field | Change |
2014-07-14 19:36 | hagenbucher | New Issue | |
2014-07-15 07:18 | fdurand | Note Added: 0003564 | |
2014-07-15 12:58 | hagenbucher | Note Added: 0003565 |